TEMPERATURE SENSORS |
|
|
Pt100 Temperature Transmitter (mpu-10) |
|
 |
- Transmitter with Profibus PA
communication
- Profile: Profibus PA, version 3.o
DPV1
- Configuration via Profibus PDM
software
- Inputs: RTD dual, RTD, T/C, mV and
R
- Galvanic isolation voltage between
input and output: 2kV (AC)
- Accuracy < 0.1°C (Pt 100)
- Sensor-trim
- Local, remote or fixed
compensation for "Cold junction"
|
|
|
|
Temperature Transmitter with Display |
|
 |
- 4-digit display with green
backlight
- Temperature measurement in °C and
°F
- Easy range select by one button
- Direct connection to the PLC
- Lower costs for wiring because of
2-wire technology
|
|
|
|
Temperature Sensor and Build-In
System |
|
 |
- Short reaction time, very compact
measure point
- Available with and without
integrated transducer
- Sensor head with reduced weight:
non-sensitive for vibrations, hygienic design of the lid (TFP-58P)
- Electrical connection by M12
plug-in (TFP-168P)
- Material stainless steel (1.4435),
material certificate 3.1.B for all mounting accessories inclusive
|
|
|
|
|
Temperature Sensor Display |
|
 |
- Application: hygienic temperature
measurement in pipes and vessels
- Integrated process connection
- Direct connection for TriClamp
1/2" up to 2"
- All medium contacted materials are
FDA conform
- High contrast LC-Display, height
15mm
- Possibility to calibrate for
finetuning of certain process temperatures
|
|
|
|
|
|
|
|
|
Temperature Sensor G1/2" Standard |
|
 |
- Application: temperature
measurement in pipes and vessels without direct contact of the
sensor of the product and remove the temperature sensor without
opening the process
- Defined position of the cable
entry
- Available with and without
integrated transmitter
- Different kinds of electrical
connections available
|
|
|
|
|
|
|
|
|
Pipe Contact Temperature Sensor |
|
 |
- Application: Temperature
measurement on pipes surfaces, for pipe diameters from DN 10 to
DN250, no contact to the product of the sensor and additional
mounting with opening the process
- Application examples: Measurement
monitoring on pipes with diameter DN10 and measurement on pipes
which where cleaned mechanically
|
|
|
|
|
|
|
|
|
Pt100 Two-wire Input Temperature Transducer (mpu-4p) |
|
 |
- Installation into the sensor head
- Configuration with PC or
programming adapter mpu-p
- Connection directly to the PLC
- Temperature linear 4-20mA signal
- Very low temperature drift
- Lead compensation up to 40W with
two-wire connection
- fully potted module
|
|
|
|
|
|
|
|
|
Level Detector with integrated
Temperature Sensor |
|
 |
- Application: level detection and
temperature measurement in one device
- Application examples: Dry running
and temperature protection in pipes,level detection and temperature
measurement in vessels
- Level detection and temperature
measurement in one measurement point
- Available with or without
integrated electronic
|
|
|
|
|
|
|
|
|
Temperature Sensor Fermenter
Connection |
|
 |
- Application: For plants in the
pharmaceutical industries and temperature measurement in fermenter
connection
- Application examples: process
monitoring, controlling of CIP/SIP process and temperature
monitoring
- Sensor probe e-polished Ra <
0.8 mm
(standard)
- Material of wetted parts 1.4435
(316L)
- Available with or without
integrated transmitter
- Material certificate acc. EN
10204-3.1.B
|
|
|
|
|
|
|
|
|
Temperature Sensor
(TFP-17, TFP-18) |
|
 |
Temperature measurement with temperature
sensors Pt100 operates on the basis of the change in resistance of
platinum as a function of temperature fluctuations. The electrical
connection is made by a 2, 3 or 4-wire system, depending on the input of
the display unit. As an optional alternative these temperature sensors
can be connected to a 4-20mA current input by means of an integral
two-wire transducer mpu-4, -4p (two-wire current loop). The temperature
sensor TFP-17 is suitable for measurements of gaseous media like air.
The temperature sensor TFP-18 can be mounted in each 6mm clamp screw.
According to the clamp screws EMK-25/76 resp. KEV-25/76 you will get an
hygienic measurement point without gaps (certified by EHEDG-advice).
- terminal box of PA6 plastic
material
- highly resistance to chemical
agents
- suitable in food and drug industry
- sensing resistor installed in
protecting tube (1.4571)
- fast response
|
|
|
|
|
|
|
|
|
Temperature Sensor with M12 Hygienic |
|
 |
- Application: temperature
measurement in pipes DN15...DN80 and measurement in thin-walled
pipes and vessels
- Application examples: process
monitoring, controlling of CIP- / SIP process & temperature
measurement in UHT-plants
- defined position of the cable
entry
- available with and without
integrated transmitter
- different kind of electrical
connections available
|
|
|
|
|
|